SIDOOR functions
3.2 System functions
Parameter assignment
The determination of the values for the energy limit is performed using the following
parameters:
● In closing direction: p1202
● In opening direction: p1203
● NDG mode: p1204
Parameter assignment is possible via the travel curve parameters or the terminal module.
If one of the two energy limitation parameters is set to 0, the speed limitation is suppressed
according to the kinetic energy.
3.2.9

External closing force

Description of function
Risk of injury due to moving mechanical parts
Ensure that if there is an additional, external closing force, the sum of the external closing
force and the force set in the controller does not exceed the maximum force limit of 150 N
(according to EN 953).
Check the final application-specific limit values and adjust the limit values accordingly.
3.2.10

Synchronization of the door position

Description of the function
The determined door position is set to zero when an obstruction of the door in the range of 1
cm before the learned CLOSED position has been detected or the door moves beyond the
learned CLOSED position.
As of V1.09: The determined door position is set to zero when the door has passed at least
the trained door width plus 1 cm from the OPEN position in the CLOSE direction and detects
an obstruction or the door moves beyond the trained CLOSED position.
60
WARNING
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB