F421
Torque Command Filter
Program
Torque Setting Parameters
This parameter reduces the motor vibration caused by large-inertia loads. A
small value will have a great effect while an increased value will have a lesser
effect.
Synchronized Torque Bias Input
Program
Torque Setting Parameters
This parameter Enables/Disables the Synchronized Torque Bias input
function. When enabled, this parameter identifies the source of the
Synchronized Torque Bias input signal.
Settings:
Disabled
VI/II
RR
RX
RX2 (option)
LED Keypad Option
Binary/BCD Input
Common Serial (TTL)
RS232/485
Communication Card
Tension Torque Bias Input
Program
Torque Setting Parameters
This parameter Enables/Disables the Tension Torque Bias input function and
identifies the source of the Tension Torque Bias input signal when enabled.
Settings:
Disabled
VI/II
RR
RX
RX2 (option)
LED Keypad Option
Binary/BCD Input
Common Serial (TTL)
RS232/485
Communication Card
H7 ASD Operation Manual
Torque Control
Torque Control
Torque Control
Direct Access Number — F421
Parameter Type — Numerical
Factory Default — 200.0
Changeable During Run — Yes
Minimum — 10.0
Maximum — 200.0
Direct Access Number — F422
Parameter Type — Selection list
Factory Default — Disabled
Changeable During Run — Yes
Direct Access Number — F423
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
F423
125