F594
Pattern Run #10 Run-Time Setting
Program
Pattern Run Control Parameters
⇒
This parameter sets the run-time value for the #10 Preset Speed mode when
used as part of a Pattern Run.
Pattern Run #11 Run-Time Setting
Program
⇒
Pattern Run Control Parameters
This parameter sets the run-time value for the #11 Preset Speed mode when
used as part of a Pattern Run.
Pattern Run #12 Run-Time Setting
Program
⇒
Pattern Run Control Parameters
This parameter sets the run-time value for the #12 Preset Speed mode when
used as part of a Pattern Run.
Pattern Run #13 Run-Time Setting
Program
Pattern Run Control Parameters
⇒
This parameter sets the run-time value for the #13 Preset Speed mode when
used as part of a Pattern Run.
H7 ASD Operation Manual
Preset Speeds
10
⇒
⇒
⇒
Preset Speeds
⇒
11
⇒
Preset Speeds
⇒
12
Preset Speeds
13
⇒
⇒
Direct Access Number — F594
Parameter Type — Numerical
Factory Default — 5
Changeable During Run — No
Minimum — 1
Maximum — 8000
Units — Seconds
Direct Access Number — F595
Parameter Type — Numerical
Factory Default — 5
Changeable During Run — No
Minimum — 1
Maximum — 8000
Units — Seconds
Direct Access Number — F596
Parameter Type — Numerical
Factory Default — 5
Changeable During Run — No
Minimum — 1
Maximum — 8000
Units — Seconds
Direct Access Number — F597
Parameter Type — Numerical
Factory Default — 5
Changeable During Run — No
Minimum — 1
Maximum — 8000
Units — Seconds
F597
153