F110
ON Input Terminal Assignment
Program
Terminal Selection Parameters
Assignment
ON
This parameter selects the functionality of the virtual input terminal ON. As a
virtual terminal, the ON control terminal exists only in memory and is
considered to always be in its True (or connected to CC) state.
It is often practical to assign this terminal to a function that the user desires to
be maintained regardless of external conditions or operations.
This parameter sets the programmable ON terminal to 1 of the 68 possible
functions that are listed in
Table 6 on pg.
F Input Terminal Assignment
Program
Terminal Selection Parameters
Assignment
F
This parameter selects the functionality of the F input terminal.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable F terminal to 1 of the 68 possible
functions that are listed in
Table 6 on pg.
R Input Terminal Assignment
Program
Terminal Selection Parameters
Assignment
R
This parameter selects the functionality of the R input terminal.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable R terminal to 1 of the 68 possible
functions that are listed in
Table 6 on pg.
ST Input Terminal Assignment
Program
Terminal Selection Parameters
Assignment
ST
This parameter selects the functionality of the ST input terminal.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable ST terminal to 1 of the 68 possible
functions that are listed in
Table 6 on pg.
RES Input Terminal Assignment
Program
Terminal Selection Parameters
Assignment
RES
This parameter selects the functionality of the RES input terminal.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable RES terminal to 1 of the 68 possible
functions that are listed in
Table 6 on pg.
62
Input Terminal
67.
Input Terminal
67.
Input Terminal
67.
Input Terminal
67.
Input Terminal
67.
Direct Access Number — F110
Parameter Type — Selection List
Factory Default — Unassigned
Changeable During Run — No
Direct Access Number — F111
Parameter Type — Selection List
Factory Default — Forward
Changeable During Run — No
Direct Access Number — F112
Parameter Type — Selection List
Factory Default — Reverse
Changeable During Run — No
Direct Access Number — F113
Parameter Type — Selection List
Factory Default — Standby
Changeable During Run — No
Direct Access Number — F114
Parameter Type — Selection List
Factory Default — Reset
Changeable During Run — No