Technical Data; What This Chapter Contains; Iec Data; Ratings - ABB ACS800 Hardware Manual

45 / 60 to 560 / 600 kw
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Technical data

What this chapter contains

This chapter contains the technical specifications of the drive, e.g. the ratings, sizes
and technical requirements, provisions for fulfilling the requirements for CE and
other markings, and warranty policy.

IEC data

Ratings

The IEC ratings for the ACS800-02 with 50 Hz and 60 Hz supplies are given below.
The symbols are described below the table.
ACS800-02
Nominal ratings
size
I
cont.max
A
Three-phase supply voltage 208 V, 220 V, 230 V or 240 V
-0080-2
214
-0100-2
253
-0120-2
295
-0140-2
405
-0170-2
447
-0210-2
528
-0230-2
613
-0260-2
693
-0300-2
720
Three-phase supply voltage 380 V, 400 V or 415 V
-0140-3
206
-0170-3
248
-0210-3
289
-0260-3
445
-0320-3
521
-0400-3
602
-0440-3
693
-0490-3
720
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Light-overload use Heavy-duty use
No-
overload
use
I
I
P
cont.max
max
2N
kW
A
A
326
55
211
404
75
248
432
90
290
588
110
396
588
132
440
588
160
516
840
160
598
1017
200
679
1017
200
704
326
110
202
404
132
243
432
160
284
588
200
440
588
250
516
840
315
590
1017
355
679
1017
400
704
P
I
P
N
2hd
hd
kW
A
kW
55
170
45
75
202
55
4)
90
240
55
110
316
90
132
340
90
160
370
110
160
480
132
2)
200
590
160
3)
200
635
200
110
163
90
132
202
110
1)
160
240
132
200
340
160
250
370
200
315
477
250
2)
355
590
315
3)
400
635
355
Frame
Air flow
Heat
size
dissipation
3
m
/h
W
R7
540
2900
R7
540
3450
R7
540
4050
R8
1220
5300
R8
1220
6100
R8
1220
6700
R8
1220
7600
R8
1220
7850
R8
1220
8300
R7
540
3000
R7
540
3650
R7
540
4300
R8
1220
6600
R8
1220
7150
R8
1220
8100
R8
1220
8650
R8
1220
9100
Technical data