Operation

This table describes the operation of the main circuit in short.
Component
six-pulse rectifier
capacitor bank
six-pulse IGBT inverter

Printed circuit boards

The drive contains the following printed circuit boards as standard:
• main circuit board (AINT)
• motor control and I/O board (RMIO-02) with a fibre optic link to the AINT board
• input bridge control board (AINP)
• input bridge protection board (AIBP) which includes varistors, snubbers for the
thyristors
• power supply board (APOW)
• gate driver control board (AGDR)
• diagnostics and panel interface board (ADPI)
• EMC filter boards (NRFC) with option +E202 in units with enclosure extension
• brake chopper control board (ABRC) with option +D150

Motor control

The motor control is based on the Direct Torque Control (DTC) method. Two phase
currents and DC link voltage are measured and used for the control. The third phase
current is measured for earth fault protection.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
converts the three-phase AC voltage to DC voltage
energy storage which stabilizes the intermediate circuit DC voltage
converts the DC voltage to AC voltage and vice versa. The motor
operation is controlled by switching the IGBTs.