Limitations In Data Hold/Non-Hold Function - Panasonic AFPE224300 User Manual

Fp-e series panel mounted controller
Hide thumbs Also See for AFPE224300:
Table of Contents

Advertisement

2.6 Limitations in data hold/non-hold function

Setting a system register can expand the data hold area. In this case, however, a back-up battery must be
previously installed.
Product No.
AFPE224300
AFPE224302
Note 2
AFPE224322
AFPE224305
AFPE214325
Note 1: System register settings are effective only when a back-up battery is installed in
the FP-e control unit.(A set value will be returned to the default value.)
Note 2: A back-up battery cannot be installed in this type of product.
System register setting screen – (Hold/Non-hold)
Areas for Nos. 6, 7, 8 and 14 can be expanded.
Note: "NOTICE" in the screen above is described for the FPWIN GR Ver. 2.24 or higher.
Note: System register initial values on Hold/Non-hold tab are within the ones that can be backed up
with a ROM.
2-12
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Settings
System register setting
System register setting with a back-up battery
System register setting without a back-up battery
Note 1
Data
Non-hold
Hold
Non-hold

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afpe224305Afpe224322Afpe224302Afpe214325

Table of Contents