Panasonic AFPE224300 User Manual page 84

Fp-e series panel mounted controller
Hide thumbs Also See for AFPE224300:
Table of Contents

Advertisement

Item
High-speed counter
function
* The combinations
1-phase x 2 ch. and
2-phase x 1 ch. are
also possible for
the high-speed counter.
* For details and l
imitations on the
high-speed counter,
see the following pages.
Pulse output
function
* For details
and limitations
on the high-
speed counter,
see the follow-
ing pages.
PWM output
function
* For details
and limitations
on the high-
speed counter,
see the follow-
ing pages.
Timer
Non-hold type
Counter
Hold type
Internal
Non-hold type
relay
Hold type
Data
Non-hold type
register
Hold type
Note 6) The max counting speed (10 kHz) is the counting speed with a rated input voltage of 24 V DC
and an ambient temperature of 25 ºC. The counting speed (frequency) will decrease depending
on the voltage and temperature.
Note 7) If the unit is equipped with both reset inputs X0 and X1, X2 serves as the reset input for X1. If X3
and X4 are used, X5 serves as the reset input for X4.
Note 8) When the positioning control instruction "F168" is performed, the maximum output frequency is
9.5 kHz.
Note 9) The program, system registers and the hold type area (internal relay, data register, and timer/
counter) are backed up by the built-in EEP-ROM. Data can be written 10000 times or less with
the EEP-ROM writing instruction. When a battery is replaced with a new one in the FP-e unit with
a calendar timer function, settings can be changed using the system register. If a battery is not
installed, the data cannot be stored even when the settings of the system register are changed.
Note 10) Use the following methods for holding the SV data:
1. Set the transfer instruction for the special data register (DT) to hold the data. Then, perform the
setting so that the data can be transferred from DT to SV after the RUN mode starts.
2. Use the FP-e model with a battery.
9-4
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AFPE224300
(Standard
Model
type)
RS232C
Counter mode: Addition/subtraction (1-phase)
- Input points: 4 ch. (Max.)
- Max. speed: 10 kHz (total of 4 ch.)
- Input contact: X0: count input (ch. 0)
- Min. input pulse width: X0, X1: 50µs(10 kHz)
X3 and X4: 100 µs (5kHz)
Counter mode: 2-phase/individual/direction decision (2-phase)
- Input points: 2 ch (Max.)
- Max. speed: 2 kHz (total of 2 ch.)
- Input contact: X0: count input (ch. 0)
- Min. input pulse width: X0, X1: 50µs(10 kHz)
X3 and X4: 100 µs (5 kHz)
Output
2 independent points (Y0 and Y1)
points
(No interpolation function)
Output
40 Hz to 10 kHz (Y0/Y1: 1-point)
fre-
40 Hz to 5 kHz (Y0/Y1:2-point)
quency
Output
2 points (Y0 and Y1)
points
Output
Frequency: 0. 15 Hz to 1 kHz,
fre-
Duty: 0.1 to 99.9 %
quency
Non-hold (all points)
From set value to C139
C140 to C143, EV140 to EV143 (elapsed values)
Note 10)
SV: Non-hold
976 points (R0 to R60F)
32 points (R610 to R62F)
1652 words (DT0 to DT1651)
8 words (DT1652 to DT1659)
AFPE224302
AFPE224305
(Standard
(Calendar
type)
timer
RS485
type)
RS232C
X1: count input (ch. 1)
Note 7)
X2: reset input
X3: count input (ch. 2)
X4: count input (ch. 3)
Note 7)
X5: reset input
X1: count input (ch. 0)
X2: reset input
X3: count input (ch. 2)
X4: count input (ch. 2)
X5: reset input
Note 8)
SV: Hold
61 words (WR0 to WR60)
2 words (WR61 to WR62)
AFPE214325
AFPE224322
(Thermo-
(Thermo-
couple input
couple input
type)
type)
RS232C
RS485
Note 6)
:Max. 5 kHz
X0, X1: 100µs (5 kHz)
:Max. 1 kHz
X0, X1: 100µs (5 kHz)
40Hz to 5kHz (1-point)
40Hz to 2.5kHz (2-point)
SV: Non-hold
Note 10)