Reading/Writing Parameters From/To Devices Supporting Iqss - Mitsubishi Electric IQSS-R-E Reference Manual

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

5.3
Reading/Writing Parameters from/to Devices
Supporting iQSS
Parameters can be read from and written to a slave station.
For the operation methods of the "CC IE Field Configuration" window, refer to the following manual.
 GX Works2 Version 1 Operating Manual (Common)
Window
1.
Select a target module in the 'List of stations' or 'Device map area' in the "CC IE Field Configuration" window, and select
[CC IE Field Configuration]  [Online]  [Parameter Processing of Slave Station].
2.
Read/write the parameters on the "Parameter Processing of Slave Station" screen.
• The data backup/restoration function is useful to read/write the parameters of multiple devices supporting
iQSS in a batch. (Page 108 Backing up/Restoring Data of Devices Supporting iQSS)
• The useful function (linkage with dedicated tools) can also be used in the "CC IE Field Configuration"
window. (Page 323 Linkage with dedicated tools (association with properties))
■Display methods of the "Parameter Processing of Slave Station" screen
The "Parameter Processing of Slave Station" screen can also be displayed by any of the following operations.
• Select a target module in 'List of stations' or 'Device map area' in the "CC IE Field Configuration" window, then right-click
and select [Online]  [Parameter Processing of Slave Station] from the shortcut menu.
• Select a target module in the 'List of stations' or 'Device map area' on the "Sensor/Device Monitor for CC IE Field" screen,
and select [Online]  [Parameter Processing of Slave Station].
• Select a target module in the 'List of stations' or 'Device map area' on the "Sensor/Device Monitor for CC IE Field" screen,
then right-click and select [Parameter Processing of Slave Station] from the shortcut menu.
For details on the "Sensor/Device Monitor for CC IE Field" screen, refer to the following section.
Page 107 Monitoring Devices Supporting iQSS
■Display method of a device supporting iQSS, which is connected to a bridge module
(NZ2AW1GFAL) on the "Parameter Processing of Slave Module" screen
Window
2. Select
1. Select
1.
Select a bridge module (NZ2AW1GFAL) in 'List of stations' or
'Device map area' in the "CC IE Field Configuration" window.
2.
Select [CC IE Field Configuration]  [Open System
Configuration]  [Open AnyWireASLINK Configuration].
3.
Select a target device supporting iQSS in 'List of modules' or
'Device map area' in the "AnyWireASLINK Configuration"
window, and select [AnyWireASLINK Configuration] 
[Online]  [Parameter Processing of Slave Module].
4.
Read/write the parameters on the "Parameter Processing of
Slave Module" screen.

5.3 Reading/Writing Parameters from/to Devices Supporting iQSS

5 CC-Link IE Field Network
5
105

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28

Table of Contents