Mitsubishi Electric IQSS-R-E Reference Manual page 30

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

2. Click
Select
• The system configuration cannot be detected if an error occurs on the AnyWireASLINK master module.
Take corrective actions and perform an automatic detection of connected devices again.
• Error information is displayed in the "Output" window when an error occurred.
Double-click it and correct the error at the jumped destination.
• When a module which is not a device supporting iQSS is detected, it is displayed as shown below:
"Module with No Profile Found"
"General Module"
■Detection methods of a system configuration
The system configuration of AnyWireASLINK can also be detected by either of the following operations.
• Click the [Detect Now] button in the "AnyWireASLINK Configuration" window.
• Select [Online]  [Detect Now] in MELSOFT Navigator. (FXCPUs do not support this function.)
For the operation methods of MELSOFT Navigator, refer to the following manual.
(Let's start iQ Works Version 2)
3 AnyWireASLINK
28
3.1 Detecting Devices Supporting iQSS Automatically
1. Check
List of modules
Device map area
Output window
5.
When an automatic address detection is required, select the
"Execute Detect Now after Address Auto-recognition"
checkbox, then click the [Yes] button.
For a case in which an automatic address detection is required,
refer to the following manual.
MELSEC-Q/L AnyWireASLINK Master Module User's Manual
The actual system configuration is displayed in the
"AnyWireASLINK Configuration" window.
6.
Select [AnyWireASLINK Configuration]  [Close with Saving
the Setting] in the "AnyWireASLINK Configuration" window.
The setting in the "AnyWireASLINK Configuration" window is
saved and completed.