Backing Up/Restoring Data Of Devices Supporting Iqss - Mitsubishi Electric IQSS-R-E Reference Manual

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

3.5
Backing up/Restoring Data of Devices Supporting
iQSS
Backing up the information of a device supporting iQSS to an SD memory card and restoring it to a module simplifies the
setting change for changeover.
M0
0
FMOV K0
D5000
K4
RST
M3000
RST
M3500
SET
M1000
M1000 SD1288.A
72
SET
M1100
M1100
104
=
H0
SD1436
MOV
H1050
D1000
MOV
D1000
SD1435
SET
M1200
M1200
173
=
D1000
SD1436
SET
M1300
<>
D1000
SD1436
<>
H0
SD1436
SET
M3550
M1300
234
MOV
H103
SD1437
MOV
H0FFFF SD1438
MOV
H3FF
SD1439
MOV
H1
SD1444
SET
SM1436
SD memory card
iQSS
ASLINK
20141210_12
0003_IN_ _0513
Address 1
Setting data of
ID513 (201H)
0003_IN_ _0517
Address 5
Setting data of
ID517 (205H)
In such a case as limited production of diversified products, the data backup/restoration function is useful for
switching multiple sensor settings from for product A to for product B in a batch.
Function
Data backup
Data restoration
Data backup/restoration
command
Data backup
Address 1
ID513 (201H)
Setting data
Data restoration
Data backup
Data restoration
Reference
Page 37 Data backup
Page 38 Program execution for data backup
Page 45 Data restoration
Page 46 Program execution for data restoration
Address 1 to 4
ID513 (201H) to
ID516 (204H)
Address 5
ID517 (205H)
Setting data

3.5 Backing up/Restoring Data of Devices Supporting iQSS

Address 5
ID517 (205H)
3 AnyWireASLINK