Mitsubishi Electric IQSS-R-E Reference Manual page 367

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

Number
Name
SD1378
iQ Sensor Solution
backup/restoration error
target module/execution
unit information
SD1379
iQ Sensor Solution
backup/restoration error
folder number
information
SD1380
iQ Sensor Solution
backup/restoration error
information (target
module)
SD1381
iQ Sensor Solution
backup/restoration error
device information
(target device 1)
SD1382
iQ Sensor Solution
backup/restoration error
device information
(target device 2)
*1 b1 is stored when an SD memory card is used for the Ethernet function of a CPU module.
*2 Start I/O number indicates the first three digits in four-digit hexadecimal representation.
*3 For RnENCPU, use the Ethernet port of the CPU part.
Description
Details
Module/execution unit
This register stores the target module type and execution unit
information
information when an iQ Sensor Solution backup/restoration error
occurred. When errors are detected in multiple devices, the information
of the device where the error is detected first is stored.
■Lower 8 bits (target module type)
• 1H: AnyWireASLINK
• 2H: CC-Link
• 3H: Ethernet
• 4H: CC-Link IE Field Network
■Upper 8 bits (execution unit)
<AnyWireASLINK>
• 1H: Module unit
• 2H: ID unit
<CC-Link, CC-Link IE Field Network>
• 1H: Module unit
• 2H: Station unit
• 3H: Station sub-ID unit
<Ethernet>
• 1H: Module unit
• 2H: IP address unit
This register is cleared to '0' when a right to use is acquired or a backup/
restoration is requested.
Error folder number
This register stores the target folder number (0 to 99) when an iQ Sensor
information
Solution backup/restoration error occurred. If the folder number cannot
be identified or a backup error is detected before creating a backup
folder (I/O number_station number), 'FFFFH' will be stored.
This register is cleared to '0' when a right to use is acquired or a backup/
restoration is requested.
Information of the device
This register stores the information of the device (target module) where
(target module) where an
an iQ Sensor Solution backup/restoration error occurred. When errors
error occurred
are detected in multiple devices, the information of the target device
(target module) where the error detected first is stored.
• Start I/O No.
• 03FFH: Built-in Ethernet
This register is cleared to '0' when a right to use is acquired or a backup/
restoration is requested.
Information of the device
This register stores the information of the device (target device 1) where
(target device 1) where
an iQ Sensor Solution backup/restoration error occurred. When errors
an error occurred
are detected in multiple devices, the information of the device (target
device 1) where the error detected first is stored.
<AnyWireASLINK>
• ID number
<CC-Link, CC-Link IE Field Network>
• Station number
<Ethernet>
• IP address (lower 16 bits)
This register is cleared to '0' when a right to use is acquired or a backup/
restoration is requested.
Information of the device
This register stores the information of the device (target device 2) where
(target device 2) where
an iQ Sensor Solution backup/restoration error occurred. When errors
an error occurred
are detected in multiple devices, the information of the device (target
device 2) where the error detected first is stored.
<AnyWireASLINK>
• 0 (Not used)
<CC-Link, CC-Link IE Field Network>
• Station sub-ID number
<Ethernet>
• IP address (upper 16 bits)
This register is cleared to '0' when a right to use is acquired or a backup/
restoration is requested.
*2
: Module
*3
Appendix 6 Special Relay (SM)/Special Register (SD) List
Set by
(setting
timing)
S (status
change/error)
S (status
change/error)
S (status
change/error)
A
S (status
change/error)
S (status
change/error)
APPX
365

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28

Table of Contents