Siemens Acuson S1000 Instructions For Use Manual page 476

Diagnostic ultrasound system
Table of Contents

Advertisement

A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 4P1
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Focus (cm)
Res/Speed
Ensemble Size
Frequency (MHz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 4P1
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
F - 3 4
Operating mode: Color / Power
MI
Scan
1.34
1.16
Units
(MPa)
1.91
(mW)
142.99
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
2.70
pi,α
(cm)
(MHz)
2.01
2.48
X (cm)
0.94
Y (cm)
1.60
(µsec)
2.06
(Hz)
13.57
(MPa)
2.23
pi
(cm)
pi
(cm)
4.00
(cm)
5.00
2
(W/cm
)
146.54
4.00
4.00
5
5
7
7
2.00
2.50
Operating mode: Pulsed Doppler
MI
Scan
1.34
-
Units
(MPa)
1.91
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
2.70
pi,α
(cm)
(MHz)
2.01
-
X (cm)
-
Y (cm)
-
(µsec)
2.06
(Hz)
1220.70
(MPa)
2.23
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
146.54
2.00
-
4.00
-
0.30
-
1220.7
-
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
1.12
2.77
-
164.91
69.98
3.70
2.87
6.30
0.31
-
3.36
3.36
-
1.80
1.80
-
1.60
1.60
0.28
-
7.65
-
5.00
-
3.50
3.50
-
7.65
7.65
-
0.30
0.30
-
8223
8223
TIC
2.73
142.99
2.48
0.94
1.60
4.00
5.00
4.00
5
7
2.50
TIC
2.15
164.91
3.36
1.80
1.60
7.65
5.00
3.50
7.65
0.30
8223
I n s t r u c t i o n s f o r U s e

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acuson s2000Acuson s3000

Table of Contents