A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 7CF2
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 7CF2
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
F - 6 4
Operating mode: Pulsed Doppler
MI
Scan
1.16
-
Units
(MPa)
1.86
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
4.00
pi,α
(cm)
(MHz)
2.62
-
X (cm)
-
Y (cm)
-
(µsec)
1.75
(Hz)
100.16
(MPa)
2.63
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
176.99
2.50
-
5.00
-
0.20
-
100.16
-
Operating mode: M-Mode
MI
Scan
1.34
-
Units
(MPa)
2.30
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
3.40
pi,α
(cm)
(MHz)
3.01
-
X (cm)
-
Y (cm)
-
(µsec)
0.77
(Hz)
600.00
(MPa)
3.21
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
225.96
3.00
-
4.00
-
1.00
-
600.00
-
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
0.86
2.35
-
81.64
69.30
4.40
2.98
3.60
0.41
-
2.61
2.62
-
2.83
1.16
-
1.10
1.10
0.38
-
11.96
-
6.00
-
2.50
2.50
-
11.96
5.02
-
0.20
0.20
-
20833
22321
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
0.55
0.96
-
55.13
39.54
3.50
2.85
3.30
0.66
-
2.94
2.92
-
2.58
1.41
-
1.10
1.10
18.17
-
20.00
-
6.00
-
3.00
3.00
-
20.00
6.00
-
1.00
1.00
-
600
600
TIC
2.04
194.73
2.58
4.08
1.10
16.95
6.00
2.50
16.95
0.20
19531
TIC
1.07
81.49
2.97
2.58
1.10
20.00
6.00
3.00
20.00
1.00
600