Siemens Acuson S1000 Instructions For Use Manual page 493

Diagnostic ultrasound system
Table of Contents

Advertisement

Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: V7M
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: V7M
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
I n s t r u c t i o n s f o r U s e
Operating mode: Pulsed Doppler
MI
Scan
1.48
-
Units
(MPa)
2.94
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
1.80
pi,α
(cm)
(MHz)
3.92
-
X (cm)
-
Y (cm)
-
(µsec)
1.00
(Hz)
100.16
(MPa)
3.67
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
405.85
4.00
-
3.01
-
0.15
-
100.16
-
Operating mode: M-Mode
MI
Scan
1.16
-
Units
(MPa)
2.30
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
2.20
pi,α
(cm)
(MHz)
3.92
-
X (cm)
-
Y (cm)
-
(µsec)
0.47
(Hz)
600.00
(MPa)
3.05
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
232.41
4.00
-
3.00
-
1.00
-
600.00
-
A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
0.45
-
1.48
23.57
23.57
-
-
-
1.90
0.21
4.00
-
4.00
0.75
-
0.75
0.73
-
0.73
0.21
3.00
-
3.00
-
4.00
-
4.00
3.00
-
3.00
0.15
-
0.15
15625
-
15625
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
0.34
-
0.72
17.84
17.24
-
-
-
2.10
0.30
3.98
-
4.00
1.02
-
1.02
0.73
-
0.73
9.58
11.00
-
3.00
-
4.00
-
4.00
11.00
-
7.00
1.00
-
1.00
600
-
600
TIC
0.71
23.57
3.98
0.75
0.73
3.00
3.00
4.00
3.00
0.15
15625
TIC
0.46
17.84
4.00
1.02
0.73
11.00
3.00
4.00
11.00
1.00
600
F - 5 1