Gas Types; Figure 2-24 Available Sample Conditioning Modules; Table 2-10 Sample Conditioning Module Descriptions - ABB NGC8206 User Manual

Chromatograph
Hide thumbs Also See for NGC8206:
Table of Contents

Advertisement

2.16.1 Gas Types

The user can select from one of four sample conditioning modules for installations
whose gas samples do not meet the ideal clean and dry conditions. The following
definitions define what is meant by the condition of natural gas to be sampled.
2102024-001

Figure 2-24 Available Sample Conditioning Modules

Part Number
Description
Designed for sample point distances greater than 10' (3 m) and less than 150' (50 m) with
known particulate and liquid contamination. For stable gas samples containing pipe scale
and other solid contaminates and possibly minor amounts of liquid contamination. System
2102024-001
features:
Designed for sample point distance greater than 50' (15m) and less than 150' (50m). The
sample gas is known to contain particulate and liquid contamination with a good
probability of line flooding in upset conditions, enough at times to overflow the coalescer
2102494-001
(a+ avenger) filter. It also has a Genie membrane for liquid rejection and a Genie liquid
shut off to be used when liquid carry over would harm the chromatograph if it was
introduced as a sample. This model contains a liquid shut off to protect the GC. The liquid
shut off resets itself when liquids are no longer present.
Page 2–34
Clean gas is defined as having no particles larger than one micron and no
more than one milligram of solids per cubic meter of gas.
Dry gas is defined as having no more than seven pounds of water per million
cubic feet of gas. Gas has less than 0.1 PPM of liquid at the coldest ambient
condition expected at the coldest point in the system. The liquid can be
water, oil, synthetic lubrication, glycol, condensed sample or any other non
vapor contaminate.
Stable gas is a vapor containing less than 0.1 PPM of liquid when vapor is
cooled to 18.3 °F (10 °C) below the coldest ambient temperature possible at
any point in the system.
2102494-001
Table 2–10 Sample Conditioning Module Descriptions
Particulate/coalescing filter
Liquid/vapor separator
2104677-001
2101510 Rev. AG

Advertisement