7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
Value table:
Bit 0
Variable message function
Bit 1
Segment variable message function
Bit 2
Comparison variable message function
Note:
Bit 1 is effective only if signal number 0 is selected in MD 1621 (signal number variable
message function).
The variable message function monitors a freely selectable memory location from address
space X or Y in the data RAM for violation of a threshold specified by the user. A tolerance
band can also be set for this threshold value which is taken into account when the threshold is
scanned for violation. This message is output via operational message with bit 5 and can be
linked to a pickup or dropout delay. The message function is executed in a 4 ms cycle.
Graphic representation
Threshold
Pickup delay time
Note:
The quantity to be monitored can be selected by specifying either a signal number or a
physical address; the physical address, however, is relevant only for Siemens servicing
purposes.
7–140
0 = not active
1 = active
0 = address space X
1 = address space Y
0 = comparison without sign
1 = comparison with sign
Message
Dropout delay time
©
Siemens AG 1992 All Rights Reserved
09.95
Tolerance band