Siemens SINUMERIK 840C Installation Instructions Manual page 442

Siemens computer drive installation instructions
Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

10.94
202
Default value
100
Input of reset time reduction factor for the upper adaptation speed. This machine data contains
the multiplication factor for the reset time characteristic (see diagram MD 203).
203
Selection adaption speed controller motor 1
Default value
0
Input of activation point for speed controller adaption. The diagram shows how the individual
machine data influence the speed characteristic.
K
, T
P
N
MD 199/MD 286
MD 31/MD 265
MD 32/MD 266
0: No speed controller adaption
1: No function assigned at present
2: Speed controller adaption activated
3: No function assigned at present
Note:
The speed controller adaption function is available only for operation in gear stage 1.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
Reduction factor reset time motor 1
Lower input limit
Upper input limit
1
Lower input limit
Upper input limit
0
n
(MD 195/MD 283)
n
1
2
Lower speed
Upper speed
6FC5197- AA50
7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
200
7
MD 202/MD 289
MD 201/MD 288
MD 198/MD 285
(MD 196/MD 284)
Active
at once
Units
%
Active
at once
Units
n
7–27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents