ISSUE 1.0
T: Tip
R: Ring
H: High
L: Low
Modular Cable
(4-wire, Straight)
4W Hybrid Multiline
Figure 2-68 Hybrid/Analog Extension Cabling of 008U-C1
3.4.4.1 Connectors
The following table shows the pin-outs for the RJ-61 cable connector for Hybrid/Analog extension
connections.
8 765 4321
Hardware Manual
008U-C1
Trunks
HYB/SLI 1 - 8
HYB/SLI 8
T
R
L
H
L
Exit
Help
ABC
DEF
Flash
Transfer
1
2
3
GHI
JKL
MNO
Mute
DND
4
5
6
PQRS
TUV
WXYZ
Clear/Back
7
8
9
0
#
Speaker
Hold
Hybrid 4W DSS
Telephone
Console
Table 2-17 RJ-61 Hybrid/Analog Pin-Outs (J4)
Pin No.
1
2
3
4
5
6
7
8
HYB/SLI
1-2
3-4
5-6
7-8
H
Modular Cable
(2-wire, Straight)
Pin Function (HYB/SLI: 1-2 / 3-4 / 5-6 / 7-8)
HYB Data 2/4/6/8 (H)
HYB Data 1/3/5/7 (H)
HYB/SLI 2/4/6/8 (Tip)
HYB/SLI 1/3/5/7 (Ring)
HYB/SLI 1/3/5/7 (Tip)
HYB/SLI 2/4/6/8 (Ring)
HYB Data 1/3/5/7 (L)
HYB Data 2/4/6/8 (L)
SL2100
HYB/SLI 1 - 8
T
R
5
6
SLT
2-51