Siemens SINUMERIK 804D sl Commissioning Manual page 241

Cnc part 1 nck, plc, drive
Table of Contents

Advertisement

Statements
NcddeDefaultMachineName = AddressParameter
NcddeMachineNames = AddressParameter
[ AddressParameter ]
ADDRESS0 = IP address, LINE=10,NAME=/NC, SAP=030d, PROFILE=CLT1__CP_L4_INT
ADDRESS1 = IP address, LINE=10,NAME=/PLC, SAP=0201, PROFILE=CLT1__CP_L4_INT
ADDRESS2 = IP address, LINE=10, NAME=/DRIVE0, SAP=0900, PROFILE=CLT1__CP_L4_INT
ADDRESS3 = IP address, LINE=10, NAME=/DRIVE1, SAP=0a00, PROFILE=CLT1__CP_L4_INT
ADDRESS4 = IP address, LINE=10, NAME=/DRIVE2, SAP=0b00, PROFILE=CLT1__CP_L4_INT
ADDRESS5 = IP address, LINE=10, NAME=/DRIVE3, SAP=0c00, PROFILE=CLT1__CP_L4_INT
ADDRESS6 = IP address, LINE=10, NAME=/DRIVE4, SAP=0d00, PROFILE=CLT1__CP_L4_INT
ADDRESS7 = IP address, LINE=10, NAME=/DRIVE5, SAP=0e00, PROFILE=CLT1__CP_L4_INT
Multiple SINUMERIK control systems
If you require communication with multiple SINUMERIK control systems you must create a
section
AddressParameter
[
control system with the relevant IP address.
In the [ GLOBAL ] section, you must specify the section name for the SINUMERIK control
system, e.g. [ 840D_001 ], with which communication should occur once the Automation
License Manager has booted.
Notice
Editing the IP address
The IP address specified in the user-specific initialization file MMC.INI influences not only the
Automation License Manager but also all other applications installed on the same computer
(PC/PG) that use HMI basic software (e.g. HMI Advanced).
To apply the change to the active IP address, you must close all active applications using
HMI basic software (e.g. HMI Advanced). Once you have closed all applications, restart the
computer to activate the new IP address.
Requirements
The following conditions must be fulfilled:
• The HMI basic software is installed on the computer (PC/PG) on which the Automation
• The IP addresses of the SINUMERIK control systems with which the Automation License
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0
] with a unique name e.g. [ 840D_001 ], [ 840D_002 ], etc. for each
License Manager is running.
Manager must communicate are known.
14.9 Assigning via Automation License Manager
Licensing
241

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120Sinumerik 840de sl

Table of Contents