Esd Notices - Siemens SINUMERIK 804D sl Commissioning Manual

Cnc part 1 nck, plc, drive
Table of Contents

Advertisement

2.2

ESD notices

Caution
The modules contain electrostatically sensitive devices. Discharge yourself of electrostatic
energy before touching the components. The easiest way to do this is to touch a conductive,
grounded object immediately beforehand (for example, bare metal parts of control cabinet or
the protective ground contact of a socket outlet).
Notice
Handling ESD-modules:
• When handling electrostatically sensitive devices, make sure that operator, workplace
• Generally, electronic modules must not be touched unless work has to be carried out on
• Touch components only if:
• Modules may only be placed on electrically conductive surfaces (table with ESD top,
• Keep modules away from visual display units, monitors or TV sets (minimum distance
• Do not bring ESD-sensitive modules into contact with chargeable and highly-insulating
• Measurements on modules are allowed only if:
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0
and packing material are properly grounded.
them. When handling PCBs make absolutely sure that you do not touch component pins
or printed conductors.
– You are permanently grounded via an ESD armband
– You are wearing ESD shoes or ESD shoe-grounding-strips, if ESD flooring is available
conductive ESD foam plastic, ESD packaging bags, ESD transport containers).
from screen 10 cm).
materials, such as plastic, insulating table tops or clothing made of synthetic materials.
– The measuring instrument is properly earthed (e.g., protective conductor) or
– Before measuring with a floating measuring instrument, the probe is briefly discharged
(e.g., touch the bare metal parts of the control housing).
Safety information
2.2 ESD notices
23