Measuring Solenoid Valve Output Pressure - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00228-04
Measuring solenoid valve output
pressure
a Measuring tools for solenoid valve output pres-
sure
Symbol
Part No.
799-101-5002 Hydraulic tester
1
N
790-261-1204 Digital hydraulic tester
2
799-401-3100 Adapter (Size 02)
k
Stop the machine on a level ground and
lower the work equipment to the ground.
Then, release the residual pressure from
the hydraulic circuit. For details, see
"Releasing residual pressure from hydrau-
lic circuit".
a Before measuring the solenoid valve output
pressure, check that the basic pressure of the
control circuit is normal.
a Measure the solenoid valve output pressure
under the following condition.
Hydraulic oil temperature: Within operating
q
range
1.
Disconnect outlet hoses (1) – (6) of the sole-
noid valves to be measured.
No.
Solenoid valve to be measured
1
PPC lock solenoid valve
2
2-stage relief solenoid valve
3
Swing holding brake solenoid valve
4
Travel speed shifting solenoid valve
5
Travel junction solenoid valve
ATT return selector solenoid valve
6
(Attachment installation specification)
a When measuring with hose (1), remove
the undercover (rear side) of the opera-
tor's cab.
42
1
Part name
a When measuring with hoses (2) – (6),
remove the undercover of the control
valve.
2.
Install adapter N2 and connect the discon-
nected hose again.
3.
Install nipple [1] of hydraulic tester N1 and con-
nect it to oil pressure gauge [2].
a Use the oil pressure gauge of 5.9 MPa {60
2
kg/cm
}.
a The figure shows the measuring tools con-
nected to outlet hose (1) of the PPC lock
solenoid valve.
4.
Start the engine.
5.
Run the engine at high idle, operate the control
levers and switches to turn the solenoid valve
ON or OFF, and measure the oil pressure.
a For the conditions for turning the solenoid
valve ON and OFF, see the operation
table of each solenoid valve.
a The operating condition of the solenoid
valve can be checked with the monitoring
function of the machine monitor (For
details, see "Special functions of machine
monitor").
Monitoring code: 02300 Solenoid 1
q
Monitoring code: 02301 Solenoid 2
q
30 Testing and adjusting
PC210, 230, 240-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc240lc-8Pc240nlc-8Pc210nlc-8Pc210lc-8Pc230nhd-8

Table of Contents