Information In Troubleshooting Table - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00240-01

Information in troubleshooting table

a The following information is summarized in the troubleshooting table and the related electrical circuit
diagram. Before carrying out troubleshooting, understand that information fully.
User code
Failure code
Display on
Display on machine
machine moni-
monitor
tor
Contents of
Contents of trouble detected by machine monitor or controller
trouble
Action of
Action taken by machine monitor or controller to protect system or devices when engine con-
machine moni-
troller detects trouble
tor or controller
Problem that
Problem that appears on machine as result of action taken by machine monitor or controller
appears on
(shown above)
machine
Related infor-
Information related to detected trouble or troubleshooting
mation
1
2
Possible causes
Possible causes of trouble
and standard
(Given numbers are refer-
value in normal
ence numbers, which do not
state
indicate priority)
3
4
14
Trouble
Trouble name displayed in abnormality record machine monitor
Cause
Standard value in normal state/Remarks on troubleshooting
<Contents of description>
• Standard value in normal state to judge possible causes
• Remarks on judgment
<Troubles in wiring harness>
• Disconnection
Connector is connected imperfectly or wiring harness is bro-
ken.
• Ground fault
Wiring harness which is not connected to chassis ground
circuit is in contact with chassis ground circuit.
• Hot short
Wiring harness which is not connected to power source (24
V) circuit is in contact with power source (24 V) circuit.
• Short circuit
Independent wiring harnesses are in contact with each other
abnormally.
<Precautions for troubleshooting>
(1) Method of indicating connector No. and handling of T-
(2) Entry order of pin Nos. and handling of tester leads
adapter
Insert or connect T-adapter as explained below for trouble-
shooting, unless otherwise specified.
• If connector No. has no marks of "male" and "female",
disconnect connector and insert T-adapters in both male
side and female side.
• If connector No. has marks of "male" and "female", dis-
connect connector and connect T-adapter to only male
side or female side.
Connect positive (+) lead and negative (–) lead of tester as
explained below for troubleshooting, unless otherwise
specified.
• Connect positive (+) lead to pin No. or wiring harness
entered on front side.
• Connect negative (–) lead to pin No. or harness entered
on rear side.
40 Troubleshooting
1
PC210, 230, 240-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc240lc-8Pc240nlc-8Pc210nlc-8Pc210lc-8Pc230nhd-8

Table of Contents