Air Conditioner Does Not Operate Normally - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00244-02
E-23 Air conditioner does not operate normally
(including air conditioner abnormality record)
Trouble
(1) When air conditioner switch is operated, air conditioner control screen is not displayed.
Related infor-
• Condition of air conditioner switch signal can be checked with monitoring function.
mation
(Code: 04505 Monitor 3rd, 4th line switches, 04506 Monitor 5th line switch)
Possible causes
and standard
value in normal
1 Defective machine monitor
state
Trouble
(2) When air conditioner switch is operated, air conditioner does not operate at all.
Related infor-
mation
1 Defective fuse No. 11
2 Defective fuse in unit
Disconnection in wiring har-
ness (Disconnection in wiring
3
or defective contact in con-
nector)
Possible causes
and standard
Ground fault in wiring har-
value in normal
4
ness (Short circuit with GND
state
circuit)
Defective air conditioner con-
5
troller
6 Defective machine monitor
50
Cause
Machine monitor may be defective. (Since trouble is in system,
troubleshooting cannot be carried out.)
Cause
If fuse is broken, circuit probably has ground fault. (See cause 4.)
If fuse in unit is broken, circuit in unit probably has ground fault.
(See cause 4.)
a Prepare with starting switch OFF, then carry out troubleshooting
Wiring harness between F01-11 – fuse in
unit – AC
Wiring harness between AC
(16) – chassis ground (T07)
a Prepare with starting switch OFF, then carry out troubleshooting
Wiring harness between F01-11 – fuse in
unit – AC
end
a Prepare with starting switch OFF, then turn starting switch ON
If above voltage is normal, air conditioner controller may be defec-
tive.
If causes 1 – 5 are not detected, machine monitor may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.)
Standard value in normal state/Remarks on troubleshooting
Standard value in normal state/Remarks on troubleshooting
without turning starting switch ON.
(wiring side) (6)
W
W
without turning starting switch ON.
(wiring side) (6), – circuit branch
W
and carry out troubleshooting.
AC
(wiring side)
W
Between (6) – (16)
40 Troubleshooting
Resist-
ance
(wiring side)
Resist-
ance
Resist-
ance
Voltage
20 – 30 V
PC210, 230, 240-8
1
Max. 1 z
Max. 1 z
Min. 1 Mz

Advertisement