Work Equipment, Swing, And Travel Systems Do Not Work; Abnormal Sound Comes Out From Around Hydraulic Pump - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00245-02
H-3 Work equipment, swing, and travel systems do not work
Trouble
• Whole work equipment, swing, and travel systems do not work.
Related
• Carry out all troubleshooting in power mode (P) of working mode.
information
Malfunction of PPC lock
1
solenoid valve
Possible
causes and
standard value
Malfunction of self pressure
in normal state
2
reducing valve
3 Defective piston pump
4 Defective damper
H-4 Abnormal sound comes out from around hydraulic pump
Trouble

• Abnormal sound comes out from around hydraulic pump

Related
information
Lowering of hydraulic oil
1
level
Possible
2 Defective hydraulic oil
causes and
Clogging of hydraulic tank
standard value
3
cap
in normal state
Clogging of hydraulic tank
4
strainer
5 Defective piston pump
10
Cause
Standard value in normal state/Remarks on troubleshooting
a
a
Piston pump may have malfunction or internal defect. Check it by
following method.
1)
2)
3)
Pump shaft may not revolve because of defect in damper. Check
damper directly.
Cause
Standard value in normal state/Remarks on troubleshooting
Hydraulic oil level may be low. Check it directly.
Air may be in hydraulic oil. Check oil directly.
Negative pressure may be generated in hydraulic tank because of
clogged hydraulic tank cap. Check cap directly.
Negative pressure may be generated in suction circuit because of
clogged hydraulic tank strainer. Check strainer directly.
Piston pump may have internal defect. Check it directly.
Prepare with engine stopped, then run engine at high idle and
carry out troubleshooting.
Lock lever
Lock
Free
Prepare with engine stopped, then run engine at high idle and
carry out troubleshooting.
Control lever
All levers in neutral
Remove pump discharge pressure pickup plugs (F and R).
Crank engine at flywheel (manually).
If oil flows out of pickup plugs, piston pump is normal.
40 Troubleshooting
PPC lock solenoid valve output
pressure
0 MPa
2
{0 kg/cm
}
2.9 MPa
2
{30 kg/cm
}
Control circuit basic pressure
2.84 – 3.43 MPa
2
{29 – 35 kg/cm
}
PC210, 230, 240-8
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc240lc-8Pc240nlc-8Pc210nlc-8Pc210lc-8Pc230nhd-8

Table of Contents