E-1 When Starting Switch Turned On, Machine Monitor Displays - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00244-02

E-1 When starting switch turned ON, machine monitor displays

Trouble
• When starting switch turned ON, machine monitor displays nothing.
• When starting switch is turned ON, machine monitor displays KOMATSU logo, screen to input pass-
word (if set), screen to check breaker mode (if set), screen of check before starting, screen to check
Related infor-
working mode and travel speed, and ordinary screen in order.
mation
• When the engine is started, the battery voltage may lower suddenly, depending on the ambient tem-
perature and the condition of the battery.
1 Low charge level of battery
Defective fusible link F05 or
2
fuse No. 20
Wrong connection of connec-
3
tor
Disconnection in wiring har-
ness (Disconnection in wiring
4
or defective contact in con-
nector)
Possible causes
and standard
value in normal
state
Ground fault in wiring har-
5
ness (Short circuit with GND
circuit)
6 Defective machine monitor
8
Cause
a Prepare with starting switch OFF, then carry out troubleshooting
If fusible link or fuse is broken, circuit probably has ground fault.
(See Cause 5.)
Machine monitor connector may be connected wrongly. Check it
directly. (Check mounting bracket plate with connector.)
a Prepare with starting switch OFF, then carry out troubleshooting
Wiring harness between battery (–) – chas-
sis ground
Wiring harness between battery (+) – R04 –
F05 (male) (1)
Wiring harness between F05 (male) (2) –
F01-16D
Wiring harness between F01-17 – J06 –
CM01 (female) (1), (2)
Wiring harness between CM01 (female) (3),
(4) – chassis ground (T05)
Wiring harness between F01-17 – H15
(female) (1)
Wiring harness between H15 (female) (5) –
J03 – CM01 (female) (14)
a Prepare with starting switch OFF, then carry out troubleshooting
Wiring harness between battery (+) – R04 –
F05 (male) (1)
Wiring harness between F05 (male) (2) –
F01-16D
Wiring harness between F01-17 – J06 –
CM01 (female) (1), (2)
Wiring harness between F01-17 – H15
(female) (1)
Wiring harness between H15 (female) (5) –
J03 – CM01 (female) (14)
a Prepare with starting switch OFF, then hold starting switch OFF
(1), (2) – (3), (4)
Standard value in normal state/Remarks on troubleshooting
without turning starting switch ON.
Battery voltage (2 pieces)
Min. 24 V
without turning starting switch ON.
without turning starting switch ON.
and ON and carry out troubleshooting in each case.
CM01
Starting switch
Between
Between
(14) – (3), (4)
40 Troubleshooting
nothing1
Electrolyte specific gravity
(1 piece)
Min. 1.26
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Resist-
ance
Voltage
OFF
20 – 30 V
ON
20 – 30 V
PC210, 230, 240-8
Max. 1 z
Max. 1 z
Max. 1 z
Max. 1 z
Max. 1 z
Max. 1 z
Max. 1 z
Min. 1 Mz
Min. 1 Mz
Min. 1 Mz
Min. 1 Mz
Min. 1 Mz