Removal And Installation Of Monitor Assembly - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00666-01
Removal and installation of
monitor assembly
Removal
k
For machine with disconnect switch:
Before starting work, turn the starting
switch to the OFF position, wait over one
minute, then switch off the battery discon-
nect switch and take out the disconnect
key.
For machine with no battery disconnect
switch:
Cut off power, wait for approx. one minute
after turning off the engine starting key
and then disconnect the negative (–) ter-
minal of the battery.
1.
Remove cap (1).
2.
Remove cover (2) and then disconnect wiring
connector P31 (3) for air conditioner sunlight
sensor (S).
3.
Remove duct (4).
4.
Remove cover (5) as follows. [*1]
1)
Insert flat-head screwdriver inside slit (SL)
and push it upward.
2)
Release lock (L) and remove the cover.
3)
Disconnect wiring connector M04 of the
cigarette lighter from the back of cover (5).
6
50 Disassembly and assembly
5.
Remove the 4 mounting bolts and lift monitor
assembly (6). [*2]
6.
Disconnect connectors CM01 (7), CM02 (8)
and CM03 (9).
a Since CM02 (8) and CM03 (9) can be
installed reversely, be careful not to mis-
take. CM 03 (9) is a green connector.
7.
Disconnect connector (10).