Failure Code [Dxa8Kb] Pc-Epc (F) Sol Short - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

40 Troubleshooting

Failure code [DXA8KB] PC-EPC (F) Sol Short

User code
Failure code
E02
DXA8KB
Contents of
• When PC-EPC (F) solenoid was driven, short circuit was detected in circuit.
trouble
Action of
• Turns output to PC-EPC (F) solenoid OFF.
controller
• Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.
Problem that
appears on
• If pump load increases, engine speed lowers largely and engine may stall.
machine
• Drive current of PC-EPC (F) solenoid can be checked with monitoring function.
Related infor-
(Code: 01300 PC-EPC solenoid current (F))
mation
• Method of reproducing failure code: Turn starting switch ON.
Defective PC-EPC (F) sole-
1
noid (Internal short circuit or
ground fault)
Defective emergency pump
2
drive switch (Internal short
circuit or ground fault)
Possible causes
and standard
value in normal
state
Ground fault in wiring har-
3
ness (Contact with GND cir-
cuit)
4 Defective pump controller
PC210, 230, 240-8
PC-EPC (F) solenoid system short
Trouble
(Pump controller system)
Cause
a Prepare with starting switch OFF, then carry out troubleshooting
Between (1) – chassis ground
a Prepare with starting switch OFF, then carry out troubleshooting
Between (2), (3) – (4)
Between (2), (3) –
chassis ground
a Prepare with starting switch OFF, then carry out troubleshooting
Wiring harness between C02 (female) (96) –
S25 (female) (3)
Wiring harness between S25 (female) (5) –
V11 (female) (2)
a Prepare with starting switch OFF, then carry out troubleshooting
Between (96) – (115), (117),
Between (96) – chassis ground
Standard value in normal state/Remarks on troubleshooting
without turning starting switch ON.
V11 (male)
Between (1) – (2)
without turning starting switch ON.
Emergency pump
S25 (male)
drive switch
without turning starting switch ON.
without turning starting switch ON.
C02 (female)
(120)
UEN00243-01
Resistance
7 – 14 z
Min. 1 Mz
Resistance
Min. 1 Mz
Normal
Min. 1 Mz
Resis-
tance
Resis-
tance
Resistance
7 – 14 z
Min. 1 Mz
1
Min. 1 Mz
Min. 1 Mz
5