Failure Code [Ca227] Sens Supply 2 Volt High Error - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00240-01

Failure code [CA227] Sens Supply 2 Volt High Error

User code
Failure code
E15
Contents of
• High voltage was detected in sensor power supply 2 circuit.
trouble
• Fixes boost pressure value and continues operation.
Action of
• Fixes charge temperature value and continues operation.
controller
• Limits output and continues operation.
Problem that
appears on
• Engine output lowers.
machine
Related infor-
• Method of reproducing failure code: Turn starting switch ON.
mation
Possible causes
Defective wiring harness
and standard
1
connector
value in normal
state
2 Defective engine controller
Circuit diagram related to sensor power supply 2
48
Trouble
CA227
Cause
Sensor power supply 2 voltage high error
(Engine controller system)
Standard value in normal state/Remarks on troubleshooting
Connecting parts between each sensor – engine wiring harness –
engine controller may be defective. Check them directly.
• Looseness of connector, breakage of lock, or breakage of seal
• Corrosion, bend, breakage, push-in, or expansion of pin
• Moisture or dirt in connector or defective insulation
If cause 1 is not detected, engine controller may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.)
40 Troubleshooting