Siemens SINUMERIK 840D sl Function Manual page 140

Sinumerik integrate amb, amc, amm
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

3 Setting up functions
3.4 Fault services
Function
Name
Trigger
event
tolerance
Add
Paste
Clipboard
Notice
If the next trigger is triggered before execution of the diagnostics actions is
completed (e.g. save data), the diagnostics actions, e.g. record data, cannot be
executed as parallel trigger evaluation is not possible. The missing of the trigger
and of course the data for this type of event cannot be prevented by the system.
The repeat frequency is generally less than one second, with high interface
demands it may be a few seconds.
3-140
Description
Name of the trigger; can be entered by the user. If
the field remains empty or is deleted, the system
generates a name from the parameters of the
trigger. The name varies according to the screen
resolution.
If the name already exists, a consecutive number
is automatically added in parentheses.
If the name is too long, the number added can
only be seen in a tooltip.
Time to be bridged between successive initiation
of individual triggers and initiation of a total trigger.
Adding or changing any number of triggers until
the limitation by the PLC data block can be
ANDed. See also: PLC performance index
Creates additional editing boxes for additional
triggers.
A trigger in the clipboard can be selected and
pasted.
The clipboard can be viewed to copy a selection
from it.
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
© Siemens AG 2006-2013 All Rights Reserved
03/2013
Type
DISPLAY
INPUT
(max. 40
characters,
all characters
are
permissible)
DISPLAY
INPUT
SELECTION
(Time values
between 500
ms and 24
hours are
possible.)
DISPLAY
ACTION
SELECTION
ACTION
ACTION
ACTION