2 Machine information
2.2 Variable monitors – time Series – measurements and measurement series
The equability test notifies the machine operator of faults and interference
resistances from feed axis elements. The curve of the recorded values indicates at
which axis position the disturbance is located. A trend analysis of the
characteristics will indicate any change in the status of the drive train.
Fig. 2-29: Measurement results of an equability test
2-50
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
03/2013