Machine Trigger "Time Trigger - Siemens SINUMERIK 840D sl Function Manual

Sinumerik integrate amb, amc, amm
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

3 Setting up functions
3.4 Fault services

3.4.10 Machine trigger "Time trigger"

Function description
The time trigger permits trigger cycles in intervals of seconds up to 99 999 days.
Various calendar functions are available for defining the trigger time.
To allow time-based triggers to be more easily coordinated in different intervals, it
is no longer necessary to manually calculate each individual start date and time for
the first trigger. Instead a uniform start date and time can be specified from which
the trigger interval starts. The trigger time calculated from the start time and interval
is immediately displayed for control.
Notice
Time data refers only to the local time set at the machine's PC regardless of
whether the clock is correct or not.
Fig. 3-36: Time trigger
Function
Time trigger
Name
3-142
Description
Name of the trigger; can be entered by the user.
If the field remains empty or is deleted, the
system generates the "Time trigger" name.
If the name already exists, a consecutive
number is automatically added in parentheses.
If the name is too long, the number added can
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
© Siemens AG 2006-2013 All Rights Reserved
03/2013
Type
DISPLAY
INPUT
(max. 100
characters;
all characters
are

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents