3 Setting up functions
3.2 Configuring measurements and measurement series
Configuring the limit values
With the equability test, one movement is carried out each forwards and back-
wards. The characteristics are calculated separately for each direction. As standard
limit values are defined for the characteristics and are the same for both directions
of movement.
Optionally limit values can be entered which can have different values for both di-
rections for each characteristic.
Fig. 3-13: Measurement series of a equability test on the PC

3.2.3 Universal axis test

Parameter description
Parameters for conducting a universal axis test:
Function
Name
Channel
Axis
Start point
3-104
Description
Name of the measurement series (measure-
ments do not have a name).
Selection of the required channel: The channel
defines the possible machine axes in the "Axis"
selection list.
Selection from the possible machine axes that
can be programmed in the selected channel.
The axis position at which the various move-
ments of the measurement begin.
The position value is never lower than this value
during measurement.
ePS Network Services, Function Manual (FH) - 03/2012
Type
INPUT
SELECTION
SELECTION
INPUT
© Siemens AG 2012 All Rights Reserved
03/2012