3 Setting up functions
3.4 Fault services

3.4.4 Machine trigger on "Alarm group"

Function description
The "alarm group" trigger can be used to respond to all alarms programmed in the
control. These alarms also include the user area for alarm numbers that are used
to program the machine functions for machine diagnostics purposes. If machine
diagnostics are not performed on the basis of alarm numbers, there is no option of
linking these error messages here. The alarm numbers that initiate triggers can be
entered individually, in groups or in series.
It is also possible to remove individual alarms or groups from a selection. In addi-
tion to this, conditions that are not meant to initiate a trigger on their own can be lin-
ked (e.g. if a particular alarm is only meant to initiate a trigger in Automatic mode).
Fig. 3-30: "Alarm group" trigger
Function
Alarm group
Name
Initiate trig-
ger at
3-128
Description
Name of the trigger; can be entered by the user. If
the field remains empty or is deleted, the system
generates a name from the parameters of the
trigger. The name varies according to the screen
resolution.
If the name already exists, a consecutive number
is automatically added in parentheses.
If the name is too long, the number added can
only be seen in a tooltip.
 Alarm occurrence
The alarm trigger works with the incoming
alarm message for at least one alarm in the
selection.
 Alarm acknowledgment
The alarm trigger works with the outgoing
alarm message for at least one alarm in the
selection.
© Siemens AG 2012 All Rights Reserved
ePS Network Services, Function Manual (FH) - 03/2012
03/2012
Type
DISPLAY
INPUT
(max. 40
characters,
all characters
are permissi-
ble)