H1: Manual and handwheel travel
4.4 Continuous manual travel
● Orientation axis 2:
– DB21, ... DBX336.6 (orientation axis 2: travel command minus) or
– DB21, ... DBX336.7 (orientation axis 2: travel command plus)
● Orientation axis 3:
– DB21, ... DBX340.6 (orientation axis 3: travel command minus) or
– DB21, ... DBX340.7 (orientation axis 3: travel command plus)
Note
A travel command set in JOG mode is canceled if the controller enable or pulse enable for the
axis to be traversed is missing. The travel command must therefore be set again after release
of the axis.
4.4.2
Parameter assignment
Jog or continuous mode
The selection of jog or continuous mode for the continuous procedure is performed NC-
specifically for all axes via the setting data:
SD41050 $SN_JOG_CONT_MODE_LEVELTRIGGRD (jog/continuous mode for JOG
continuous)
Jogging mode is the default setting.
4.4.3
Supplementary conditions
Indexing axis
An indexing axis always stops at an indexing position both in jog mode and in continuous
mode. In jog mode, the indexing axis traverses to the next indexing position in the direction of
travel, for example, when the traversing key is released
See also
T1: Indexing axes (Page 815)