M5: Measurement
8.5 Setting zeros, workpiece measuring and tool measuring
Different tools in the WCS
Figure 8-22
Settings in the system data:
Left-hand tool: Approach direction +x and tool orientation -y
System variable
$AC_MEAS_TOOL_MASK = 0x0
$AC_MEAS_DIR_APPROACH = 0
Right-hand tool: Approach direction -x and tool orientation -y
$AC_MEAS_TOOL_MASK = 0x0
$AC_MEAS_DIR_APPROACH = 1
For both tools
$AC_MEAS_Px_COORD = 0
$AC_MEAS_SET_COORD = 0
574
Two turning tools each with their own reference point
Meaning
All tool lengths are considered
(default setting)
Approach direction +x
All tool lengths are considered
(default setting)
Approach direction -x
Coordinate system of x-th measuring point =
WCS (default setting)
Coordinate system of the setpoint =
WCS (default setting)
Function Manual, 10/2015, 6FC5397-1BP40-5BA3