Item
G
Installing the Safety module
1
2
3
4
5
6
Product manual - IRC5 Compact
3HAC047138-001 Revision: G
2.11.3 Installing the Safety module DSQC1015 for SafeMove
Equipment
Harness extended Key switch
Standard toolkit
Circuit diagram
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety inform-
ation in section
DANGER - Make sure that
the main power has been switched off! on
page
33.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit please observe the safety in-
formation in section
WARNING - The unit
is sensitive to ESD! on page 34
Remove the cover of the cabinet.
Remove the computer unit.
Open the computer unit by removing the
attachment screws and lift off the cover.
Disconnect the fan connector.
CAUTION
Be careful with the fan cable when opening
and removing the upper cover. The fan
cable must not be stretched.
Remove the attachment screw on top of
the slot bracket.
© Copyright 2009-2017 ABB. All rights reserved.
2 Installation and commissioning
Note
3HAC057075-001
Used when the controller has the option
735-3 or 735-4 Additional contacts.
The contents are defined in section
ard toolkit, IRC5 on page
See
Circuit diagrams on page
Note/Illustration
See
Removing the controller cover on
page
89.
See
Replacement of computer unit on
page
138.
xx1300000684
A Attachment screws (4 pcs.)
B Cover
Continues on next page
Continued
Stand-
207.
217.
A
B
105