4 Repair
4.2 Replacement of safety board
Continued
8
9
Refitting
Use the following procedure to refit the safety board.
Always grip the board around the edges to avoid damage to the board or its
components.
1
2
3
4
5
6
7
8
130
Action
Remove the eight attachment screws.
Gently lift the safety board out.
Note
Action
DANGER
Before commencing any work inside the cabinet, please observe the safety information
in section
DANGER - Make sure that the main power has been switched off! on page
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit please observe the safety inform-
ation in section
WARNING - The unit is sensitive to ESD! on page 34
Gently lift the safety board out of the ESD safe bag and fit it into position on the safety
board plate.
Secure the safety board with its attachment screws.
Refit the safety board unit protection cover.
Reconnect all connectors.
Refit the cabinet cover.
Perform the function tests in section
features work properly.
© Copyright 2009-2017 ABB. All rights reserved.
Note/illustration
xx1400001380
Function tests on page 118
Product manual - IRC5 Compact
3HAC047138-001 Revision: G
33.