• The monitor displayed at power ON is the first monitor (the output frequency monitor, according to the initial value). Display
the monitor you want to display on the first monitor and hold down the SET key for 1 second. To return to the output
frequency monitor, display the output frequency monitor and hold down the SET key for 1 second.
Power-on monitor (first monitor)
Output frequency monitor
For example, when Pr.52 = "20" (cumulative energization time), the monitor is displayed on the operation panel as shown
below.
• Power-on monitor (first monitor)
Output frequency monitor
• Pr.774 sets the output frequency monitor, Pr.775 sets the output current monitor, and Pr.776 sets the monitor description
to be displayed at the output voltage monitor position. When Pr.774 to Pr.776 = "9999" (initial value), the Pr.52 setting
value is used.
NOTE
• On the operation panel, the Hz LED is lit while displaying the output frequency, the Hz LED blinks when displaying the set
frequency.
• When the operation panel is used, the displayed units are Hz and A only, and the others are not displayed.
 Displaying the set frequency during stop (Pr.52)
• When Pr.52 = "100", the set frequency is displayed during stop, and output frequency is displayed during running. (The Hz
LED blinks during stop and is lit during operation.)
Pr.52 setting
0
During running/stop
During stop
100
During running
*1
Displays the frequency that is output when the start command is ON. The value considers the maximum/minimum frequency and frequency
jumps. It is different from the frequency setting displayed when Pr.52 = "5".
NOTE
• During an error, the output frequency at error occurrence appears.
• During output shutoff by the MRS signal, the values displayed are the same as during a stop.
• During offline auto tuning, the tuning state monitor takes priority.
 Operation panel setting dial push display (Pr.992) (only for the standard
model)
• Use Pr.992 to select the monitor that appears when the setting dial on the operation panel is pushed.
• When Pr.992 = "0 (initial value)", keep pressing the setting dial when in PU operation mode or External/PU combined
operation mode 1 (Pr.79 Operation mode selection = "3") to show the presently set frequency.
• When Pr.992 = "100", the set frequency is displayed during stop, and output frequency is displayed during running.
Pr.992 setting
0
During running/stop
During stop
100
During running
*1
Displays the frequency that is output when the start command is ON. The value considers the maximum/minimum frequency and frequency
jumps. It is different from the frequency setting displayed when Pr.992 = "5".
232
11. (M) Item and Output Signal for Monitoring
11.2 Monitor item selection on operation panel or via communication
Second monitor
Output current monitor
• Second monitor
Output current monitor
Status
Output frequency
Output frequency
Set frequency
Output frequency
Status
Monitor displayed by the setting dial push
Set frequency
Set frequency
Output frequency
Third monitor
Output voltage monitor
• Third monitor
Cumulative energization time monitor
Output current
*1
Output current
*1
Fault monitor
With fault
• Fault monitor
With fault
Output voltage
Fault monitor
Output voltage
Fault monitor