 T: Multi-function input terminal
parameters
Parameters for the setting of the input terminals via which
commands are given to the inverter.
Pr. group
Pr.
T000
73
T001
267
T002
74
T003
822
T004
826
T005
832
T006
836
T007
849
T022
125
T040
858
T042
126
T200
C2
T201
C3
T202
125
T203
C4
T400
C5
T401
C6
T402
126
T403
C7
T410
C38
T411
C39
T412
C40
T413
C41
T700
178
T701
179
T702
180
T703
181
T704
182
T709
183
T711
184
T720
17
T740
699
T751
185
T752
186
78
3. Parameters
3.3 Parameter list (by function group number)
Name
Analog input selection
Terminal 4 input selection
Input filter time constant
Speed setting filter 1
Torque setting filter 1
Speed setting filter 2
Torque setting filter 2
Analog input offset adjustment
Terminal 2 frequency setting
gain frequency
Simple
Simple
Simple
Terminal 4 function
assignment
Terminal 4 frequency setting
gain frequency
Simple
Simple
Simple
Terminal 2 frequency setting
bias frequency
Terminal 2 frequency setting
bias
Terminal 2 frequency setting
gain frequency
Terminal 2 frequency setting
gain
Terminal 4 frequency setting
bias frequency
Terminal 4 frequency setting
bias
Terminal 4 frequency setting
gain frequency
Terminal 4 frequency setting
gain
Terminal 4 bias command
(torque/magnetic flux)
Terminal 4 bias (torque/
magnetic flux)
Terminal 4 gain command
(torque/magnetic flux)
Terminal 4 gain (torque/
magnetic flux)
STF/DI0 terminal function
selection
STR/DI1 terminal function
selection
RL terminal function selection
RM terminal function selection
RH terminal function selection
MRS terminal function
selection
RES terminal function
selection
MRS/X10 terminal input
selection
Input terminal filter
NET X1 input selection
NET X2 input selection
Pr. group
Pr.
T753
187
T754
188
T755
189
Refer
 C: Motor constant parameters
to page
266
Parameters for the applied motor setting.
266
Pr. group
Pr.
271
271
271
C100
71
271
271
C101
80
271
C102
81
273
100,
C103
9
214,
270
C104
83
273
C105
84
273
C106
702
C107
707
273
C108
724
273
C110
96
273
C111
95
273
C120
90
273
C121
91
273
C122
92
273
C123
93
273
C124
94
C125
82
273
C126
859
273
C130
706
278
C131
711
C132
712
283
C133
725
283
C135
1412
283
C150
1002
283
C182
717
283
C185
721
283
C188
720
283
C200
450
287
C201
453
283
C202
454
283
283
Name
NET X3 input selection
NET X4 input selection
NET X5 input selection
Name
Applied motor
Motor capacity
Number of motor poles
Rated motor current
Simple
Simple
Simple
Rated motor voltage
Rated motor frequency
Maximum motor frequency
Motor inertia (integer)
Motor inertia (exponent)
Auto tuning setting/status
Online auto tuning selection
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis
inductance (Ld)
Motor constant (L2)/q-axis
inductance (Lq)
Motor constant (X)
Motor excitation current
Torque current/Rated PM
motor current
Induced voltage constant (phi
f)
Motor Ld decay ratio
Motor Lq decay ratio
Motor protection current level
Motor induced voltage
constant (phi f) exponent
Lq tuning target current
adjustment coefficient
Starting resistance tuning
compensation coefficient 1
Starting magnetic pole
position detection pulse width
Starting resistance tuning
compensation coefficient
Second applied motor
Second motor capacity
Number of second motor poles
Refer
to page
283
283
283
Refer
to page
294,
299,
308
86, 299,
308
86, 299,
308
198,
299,
308
86, 299,
308
86, 299,
308
308
308
308
299,
308,
358
315
299,
308,
358
299
299,
308
299,
308
299
299
299,
308
308
308
308
308
308
308
308
308
308
294
299,
308
299,
308

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents