Analog Input Selection - Mitsubishi Electric 800 Series Instruction Manual

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

12
(T) Multi-Function Input Terminal Parameters
Purpose
To inverse the rotation direction with the
voltage/current analog input selection
(terminals 2 and 4)
To assign functions to analog input
terminals
To eliminate noise on analog inputs
To adjust analog input frequency/voltage
(current) (calibration)
To adjust analog input torque/voltage
(current) (calibration)
To assign functions to input terminals
To change the input specification (NO/NC
contact) of input signals
To assign start and forward/reverse
commands to different signals
12.1

Analog input selection

The functions to switch the analog input terminal specifications and forward/reverse rotation by the input signal polarity are
selectable.
Pr.
73
Analog input selection
T000
267
Terminal 4 input
T001
selection
266
12. (T) Multi-Function Input Terminal Parameters
12.1 Analog input selection
Analog input selection
Terminal 4 function assignment P.T040
Analog input filter
Frequency setting voltage
(current) bias and gain
Torque setting voltage (current)
bias and gain
Input terminal function
selection
Output stop signal (MRS) /
Inverter run enable signal (X10)
input selection
Start signal (STF/STR) operation
selection
Name
Initial value
1
0
Parameter to set
P.T000, P.T001
P.T002 to P.T007
P.T200 to P.T203,
P.T400 to P.T403,
P.M043
P.T410 to P.T413,
P.M043
P.T700 to P.T711,
P.T740
P.T720
P.G106
Setting
range
Switch 2: V (initial
0, 1, 10, 11
status)
6, 16
Switch 2: I
Switch 4: I (initial
0
status)
1
Switch 4 - V
2
Pr.73, Pr.267
Pr.858
Pr.74, Pr.822, Pr.826,
Pr.832, Pr.836,
Pr.849
Pr.125, Pr.126,
Pr.241, C2 to C7
Pr.241, C38 to C41
Pr.178 to Pr.189,
Pr.699
Pr.17
Pr.250
Description
The terminal 2 input specification (0 to 5 V, 0 to 10
V, 0 to 20 mA) is selectable. Also the reversible
operation setting is selectable.
Terminal 4 input, 4 to 20 mA
Terminal 4 input, 0 to 5 V
Terminal 4 input, 0 to 10 V
Refer to
page
266
270
271
273
278
283
287
291

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents