Mitsubishi Electric 800 Series Instruction Manual page 56

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Pr.100 to Pr.199
Pr.
Function
Pr.
group
117
N020
118
N021
119
N022
N023
120
N024
121
N025
122
N026
123
N027
124
N028
125
T022
126
T042
127
A612
128
A610
129
A613
130
A614
131
A601
132
A602
133
A611
134
A615
145
E103
147
F022
150
M460
151
M461
152
M462
153
M463
154
H631
156
H501
157
M430
Name
PU communication station
number
PU communication speed
PU communication stop bit
length / data length
PU communication data
length
PU communication stop bit
length
PU communication parity
check
PU communication retry
count
PU communication check
time interval
PU communication waiting
time setting
PU communication CR/LF
selection
Terminal 2 frequency setting
gain frequency
Simple
Simple
Simple
Terminal 4 frequency setting
gain frequency
Simple
Simple
Simple
PID control automatic
switchover frequency
PID action selection
PID proportional band
PID integral time
PID upper limit
PID lower limit
PID action set point
PID differential time
Parameter for manufacturer setting. Do not set.
Acceleration/deceleration
time switching frequency
Output current detection
level
Output current detection
signal delay time
Zero current detection level
Zero current detection time
Voltage reduction selection
during stall prevention
operation
Stall prevention operation
selection
OL signal output timer
Minimum
Setting range
setting
increments
0 to 31
1
48, 96, 192, 384, 576,
1
768, 1152
0, 1, 10, 11
0, 1
1
0, 1
0 to 2
1
0 to 10, 9999
1
0, 0.1 to 999.8 s, 9999 0.1 s
0 to 150 ms, 9999
1 ms
0 to 2
1
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 590 Hz, 9999
0.01 Hz
0, 20, 21, 40 to 43, 50,
51, 60, 61, 1000, 1001,
1
1010, 1011, 2000,
2001, 2010, 2011
0.1% to 1000%, 9999
0.1%
0.1 to 3600 s, 9999
0.1 s
0% to 100%, 9999
0.1%
0% to 100%, 9999
0.1%
0% to 100%, 9999
0.01%
0.01 to 10 s, 9999
0.01 s
0 to 590 Hz, 9999
0.01 Hz
0% to 400%
0.1%
0 to 10 s
0.1 s
0% to 400%
0.1%
0 to 10 s
0.01 s
1, 11
1
0 to 31, 100, 101
1
0 to 25 s, 9999
0.1 s
3.1 Parameter list (by parameter number)
Initial
Refer
Customer
*1
value
to page
setting
Gr.1
Gr.2
*6
0
*6
192
1
*6
0
1
*6
2
*6
1
*6
0
*6
9999
*6
1
60 Hz 50 Hz
273
60 Hz 50 Hz
273
9999
329
329,
0
344
329,
100%
344
329,
1 s
344
329,
9999
344
329,
9999
344
329,
9999
344
329,
9999
344
9999
158
150%
260
0 s
260
5%
260
0.5 s
260
1
214
0
214
100,
0 s
214
3. Parameters
1
2
3
4
5
6
7
8
9
10
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents