Mitsubishi Electric 800 Series Instruction Manual page 78

Compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr. group
Pr.
Upper limit warning detection
H531
1488
width
Lower limit warning detection
H532
1489
width
Upper limit fault detection
H533
1490
width
Lower limit fault detection
H534
1491
width
Load status detection signal
H535
1492
delay time / load reference
measurement waiting time
 M: Item and output signal for
monitoring
Parameters for the settings regarding the monitoring to check
the inverter's operating status and the output signals for the
monitoring.
Pr. group
Pr.
M000
37
Speed display
M001
505
Speed setting reference
Frequency / rotation speed
M003
53
unit switchover
M020
170
Watt-hour meter clear
Energization time carrying-
M021
563
over times
Monitor decimal digits
M022
268
selection
Cumulative power monitor
M023
891
digit shifted times
M030
171
Operation hour meter clear
Operating time carrying-over
M031
564
times
Frequency monitoring
*1
M040
55
reference
*1
M041
Current monitoring reference
56
M042
866
Torque monitoring reference
Analog input display unit
M043
241
switchover
Monitor negative output
M044
290
selection
M050
1106
Torque monitor filter
M051
1107
Running speed monitor filter
Excitation current monitor
M052
1108
filter
Operation panel main monitor
M100
52
selection
Operation panel monitor
M101
774
selection 1
Operation panel monitor
M102
775
selection 2
Operation panel monitor
M103
776
selection 3
Operation panel setting dial
M104
992
push monitor selection
M200
892
Load factor
Energy saving monitor
M201
893
reference (motor capacity)
Control selection during
M202
894
commercial power-supply
operation
Refer
Name
to page
219
219
219
219
219
Refer
Name
to page
226
226
226
228
228
228
228,
244
228
228
237
237
228
273
228,
237
228
228
228
228
228
228
228
228
244
244
244
Pr. group
Pr.
Power saving rate reference
M203
895
value
M204
896
Power unit cost
Power saving monitor average
M205
897
time
Power saving cumulative
M206
898
monitor clear
Operation time rate (estimated
M207
899
value)
FM terminal function selection
M300
54
[E800-1]
AM terminal function selection
M301
158
[E800-4][E800-5]
FM terminal calibration [E800-
M310
C0
1]
AM terminal calibration [E800-
M320
C1
4][E800-5]
AM output filter [E800-4][E800-
M321
867
5]
AM output offset calibration
M390
1200
[E800-4][E800-5]
RUN terminal function
M400
190
selection
M404
191
FU terminal function selection
ABC terminal function
M405
192
selection
*3
M410
DO0 output selection
313
*3
M411
DO1 output selection
314
*3
M412
DO2 output selection
315
*3
M413
DO3 output selection
316
*3
M414
DO4 output selection
317
*3
M415
DO5 output selection
318
*3
M416
DO6 output selection
319
*3
M420
RA1 output selection
320
*3
M421
RA2 output selection
321
*3
M422
RA3 output selection
322
M430
157
OL signal output timer
M431
289
Inverter output terminal filter
Output current detection
M433
166
signal retention time
M440
870
Speed detection hysteresis
M441
41
Up-to-frequency sensitivity
M442
42
Output frequency detection
Output frequency detection for
M443
43
reverse rotation
M446
865
Low speed detection
M451
193
NET Y1 output selection
M452
194
NET Y2 output selection
M453
195
NET Y3 output selection
M454
196
NET Y4 output selection
M460
150
Output current detection level
Output current detection
M461
151
signal delay time
M462
152
Zero current detection level
M463
153
Zero current detection time
Output current detection
M464
167
operation selection
M470
864
Torque detection
3.3 Parameter list (by function group number)
Refer
Name
to page
244
244
244
244
244
237
237
241
241
241
241
250
250
250
250
250
250
250
250
250
250
250
250
250
100,
214
250
260
257
257
257
257
257
250
250
250
250
260
260
260
260
260
262
77
3. Parameters
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading