B3: Several operator panels connected to several NCUs, distributed systems - only 840D sl
Step 2a):
Load file NETNAMES.INI
HMI Advanced/PCU50: Once the NETNAMES.INI file has been created, it is transferred into
the USER directory of the PCU
Step 1b):
Operator panel 2
Entries for HMI Embedded/PCU20:
[own]
owner= PCU20
; Connection entry
[conn PCU20]
conn_1 = NCU_1
conn_2 = NCU_2
; Network parameters
[param network]
bus= opi
; HMI descriptions
[param PCU20]
mmc_typ = 0x10
mmc_bustyp = OPI
mmc_address = 2
mstt_address = 7
name = MMC_Neben
start_mode = OFFLINE
; NCU components descriptive entry
[param NCU_1]
type = NCU_573
nck_address = 22
plc_address = 22
name = NCU1
[param NCU_2]
type = NCU_573
nck_address = 23
Extended Functions