• The following table shows the command interface for each function in the Network operation mode, determined by the
parameter settings: an external terminal or a communication interface (PU connector, Ethernet connector, or
communication option).
[Explanation of Terms in Table]
EXT: External terminal only
NET: Communication interface only
Combined: Either external terminal or communication interface
—: Neither external terminal nor communication interface
Pr.338 Communication operation command
source
Pr.339 Communication speed command source
Frequency setting through communication
Terminal 2
Terminal 4
Low-speed operation command/Remote
*1
setting (setting clear)/Stop-on-contact
RL
selection 0
Middle-speed operation command/
*1
RM
Remote setting (deceleration)
High-speed operation command/ Remote
*1
RH
setting (acceleration)
Second function selection/ Stop-on-
*1
RT
contact selection 1
*1
Terminal 4 input selection
AU
*1
Jog operation selection
JOG
*1
External thermal relay input
OH
*1
15-speed selection
REX
*1
Inverter run enable
X10
*1
PU operation external interlock
X12
*1
External DC injection brake operation start NET
X13
*1
PID control valid
X14
*1
Brake opening completion
BRI
*1
PU/External operation switchover
X16
*1
V/F switchover
X18
*1
Pre-excitation/servo ON
LX
Output stop
*1
MRS
PU operation interlock
STP
Start self-holding selection
*1
(STOP)
*1
Control mode switchover
MC
*1
Torque limit selection
TL
*1
JOG2
*1
Traverse function selection
X37
*1
Torque bias selection 1
X42
*1
Torque bias selection 2
X43
*1
Trace trigger input
TRG
*1
Trace sampling start/end
TRC
*1
Sequence start
SQ
*1
Fault clear
X51
*1
Forward rotation command
STF
*1
Reverse rotation command
STR
0: NET
0:
1:
2:
NET
EXT
EXT
NET —
NET NET —
—
EXT
—
—
EXT
NET EXT
NET EXT
NET EXT
NET
—
Combined
—
EXT
NET EXT
EXT
EXT
NET EXT
NET
EXT
NET
NET
Combined
EXT
—
NET
NET
NET
NET
NET
NET
Combined
Combined
EXT or NET
Combined
NET
NET
11.3 Start command source and frequency command source during communication operation
1: EXT
Remarks
0:
1:
2:
NET
EXT
EXT
NET
—
EXT
—
—
EXT
NET EXT
Pr.59 = "0" (multi-speed),
Pr.59 ≠ "0" (remote),
NET EXT
Pr.270 ="1" (stop-on-
contact)
NET EXT
Pr.270 = "1" (stop-on-
EXT
contact)
—
Combined
EXT
Pr.59 ="0" (multi-speed)
NET EXT
EXT
NET EXT
EXT
EXT
EXT
EXT
Pr.79 ≠ "7"
Pr.79 = "7".
When X12 signal is not
assigned.
EXT
EXT
EXT
EXT
EXT
EXT
EXT
EXT
EXT
Pr.414 = "1": Valid when
there is external or network
EXT
input.
Pr.414 = "2": External.
EXT
EXT
EXT
11. (D) Operation Command and Frequency Command
11
12
13
14
15
16
17
18
19
20
267