Mitsubishi Electric 800 Series Instruction Manual (Function page 33

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Simple mode parameters (standard model)
Pr.
Pr.
group
0
G000
Torque boost
Maximum
1
H400
frequency
Minimum
2
H401
frequency
3
G001
Base frequency
Multi-speed
4
D301
setting (high
speed)
Multi-speed
5
D302
setting (middle
speed)
Multi-speed
6
D303
setting (low speed)
7
F010
Acceleration time
8
F011
Deceleration time
H000
Electronic thermal
9
C103
O/L relay
Operation mode
79
D000
selection
Terminal 2
125
T022
frequency setting
gain frequency
Terminal 4
126
T042
frequency setting
gain frequency
User group read
160
E440
selection
PM parameter
998
E430
initialization
Automatic
999
E431
parameter setting
*1
Initial value for the FR-E820-0050(0.75K) or lower, FR-E840-0026(0.75K) or lower, and FR-E820S-0050(0.75K) or lower.
*2
Initial value for the FR-E860-0017(0.75K).
*3
Initial value for the FR-E820-0080(1.5K) to FR-E820-0175(3.7K), FR-E840-0040(1.5K) to FR-E840-0095(3.7K), and FR-E820S-0080(1.5K) or
higher.
*4
Initial value for the FR-E820-0240(5.5K), FR-E820-0330(7.5K), FR-E840-0120(5.5K), FR-E840-0170(7.5K), FR-E860-0027(1.5K), and FR-E860-
0040(2.2K).
*5
Initial value for the FR-E820-0470(11K) or higher, FR-E840-0230(11K) or higher, and FR-E860-0061(3.7K) or higher.
*6
Initial value for the FR-E820-0175(3.7K) or lower, FR-E840-0095(3.7K) or lower, FR-E860-0061(3.7K) or lower, and FR-E820S-0110(2.2K) or
lower.
*7
Initial value for the FR-E820-0240(5.5K), FR-E820-0330(7.5K), FR-E840-0120(5.5K), FR-E840-0170(7.5K), and FR-E860-0090(5.5K) or higher.
*8
Initial value for the FR-E820-0470(11K) or higher and FR-E840-0230(11K) or higher.
32
2. Basic Operation
2.4 Frequently-used parameters (simple mode parameters)
Initial value
Name
Increment
Gr.1
6%
5%
0.1%
4%
3%
2%
0.01 Hz
120 Hz
0.01 Hz
0 Hz
0.01 Hz
60 Hz
0.01 Hz
60 Hz
0.01 Hz
30 Hz
0.01 Hz
10 Hz
5 s
0.1 s
10 s
15 s
5 s
0.1 s
10 s
15 s
Inverter rated
0.01 A
current
1
0
0.01 Hz
60 Hz
0.01 Hz
60 Hz
1
0
1
0
1
9999
*10
Range
Gr.2
*1
*2
*3
0% to 30%
*4
*5
0 to 120 Hz
0 to 120 Hz
50 Hz
0 to 590 Hz
50 Hz
0 to 590 Hz
0 to 590 Hz
0 to 590 Hz
*6
*7
0 to 3600 s
*8
*6
*7
0 to 3600 s
*8
0 to 500 A
*9
0 to 4, 6, 7
50 Hz
0 to 590 Hz
50 Hz
0 to 590 Hz
0, 1, 9999
0, 8009,
8109, 9009,
9109
10, 12, 20,
21, 9999
Application
Set this parameter to obtain a higher starting
torque under V/F control. Also set this when a
loaded motor cannot be driven, the warning
"OL" occurs, and the inverter output is shut off
with the fault indication "E.OC1".
Set the upper limit for the output frequency.
Set the lower limit for the output frequency.
Set this parameter when the rated motor
frequency is 50 Hz. Check the rating plate of
the motor.
Pre-set the speeds that will be switched
among by terminals.
Set the acceleration time.
Set the deceleration time.
Protects the motor from heat. Set the rated
motor current.
Select the start and frequency command
sources.
Change the frequency at the maximum
potentiometer setting (5 V in the initial
setting).
Change the frequency at the maximum
current input (20 mA in the initial setting).
This function restricts the parameters that are
read by the operation panel and parameter
unit.
Select the PM sensorless vector control and
set the parameters that are required to drive a
PM motor.
Changes parameter settings as a batch. The
target parameters include communication
parameters for the Mitsubishi Electric human
machine interface (GOT) connection and the
parameters for the rated frequency settings of
50/60 Hz.
Refer
to
page
468
292
470
38,
43,
273
232
276
250
45,
358
47,
358
218
112
216

Advertisement