19.4.1 Details of specification changes
 Number of connectable units on the CC-Link IE Field Network Basic
Number of connectable units
Master: 1
Slave: up to 16 stations (16 stations × 1 group)
Master: 1
Slave: up to 16 stations (16 stations × 4 groups)
 Functions available for the inverters manufactured in May 2020 or later
Item
Mitsubishi Electric geared motor
Plug-in option
Stand-alone option
Added parameters
Changed parameter setting range
 Functions available for the inverters manufactured in August 2020 or
later
Item
Mitsubishi Electric Vector control
dedicated motor (SF-V5RU (1500 r/min
series))
Mitsubishi Electric high-performance
energy-saving motor with encoder
Mitsubishi Electric inverter-driven geared
motor for encoder feedback control
Plug-in option
EtherNet/IP communication specifications
PROFINET communication specifications
Added parameters
Changed parameter setting range
Added faults
SERIAL (serial number)
□□ 204 ○○○○○○ or earlier
□□ 205 ○○○○○○ or later
GM-[]
FR-A8ND E kit, FR-A8NP E-kit
Parameter unit (FR-PU07), LCD operation panel (FR-LU08)
Pr.1499, P.E107 (Pr.75)
• Setting value "13" added for Pr.52, Pr.54, Pr.158, Pr.774 to Pr.776, Pr.992, Pr.1027 to
Pr.1034
• Setting values "1800 and 1803" added for Pr.71 and Pr.450 (for 200/400 V class only)
• Setting values "10000 to 10003, and 10014 to 10017" added for Pr.75 (for the safety
communication model only)
The SF-V5RU 1.5 to 5.5 kW motors can be driven by the FR-E820-0110(2.2K) to 0330(7.5K)
inverters.
The SF-V5RUH 1.5 to 5.5 kW motors can be driven by the FR-E840-0060(2.2K) to 0170(7.5K)
inverters.
SF-PR-SC
GM-DZ, GM-DP
FR-A8AP E kit
Access to the parameters, monitor data, and terminals is available.
Inverter Configuration Object (64h)
• Inverter Parameters (12288 to 16383)
• Monitor Data (16384 to 20479)
• Inverter Control Parameters (20480 to 24575)
Access to the parameters, monitor data, and terminals is available.
• Inverter Parameters (12288 to 16383)
• Monitor Data (16384 to 20479)
• Inverter Control Parameters (20480 to 24575)
Pr.284, Pr.359, Pr.367, Pr.368, Pr.369, Pr.376, Pr.422, Pr.552, Pr.600 to Pr.604, Pr.607,
Pr.608, Pr.690, Pr.692 to Pr.696, Pr.802, Pr.823, Pr.828, Pr.833, Pr.840 to Pr.848, Pr.854,
Pr.873, Pr.877 to Pr.881, P.A107 (Pr.285)
• Setting value "8888" added for Pr.11
• Setting values "19 and 35" added for Pr.52, Pr.774 to Pr.776, Pr.992, and Pr.1027 to Pr.1034
• Setting values "30 and 33" added for Pr.71 and Pr.450
• Setting values "13, 23, 42, 43, and 74" added for Pr.178 to Pr.189
• Setting values "30 to 33, and 130 to 133" added for Pr.190 to Pr.196, and Pr.313 to Pr.319
• Setting values "30 to 33" added for Pr.320 to Pr.322
• Setting values "0 to 2, and 9" added for Pr.800
• Setting value "2" added for Pr.850
• Setting value "6" added for Pr.858
• Signal loss detection (E.ECT)
• Brake sequence fault (E.MB1 to E.MB3)
Details