• Use the following formula to find the Pr.94 setting value and set a desired value as the motor constant parameter.
The setting value of Pr.94 = (1 -
R1
I1
I2
R2/S
V
M
Equivalent circuit diagram of the motor
First motor
Second
Pr.
motor Pr.
82
455
90
458
91
459
92
460
93
461
94
462
859
860
298
560
717
741
720
737
NOTE
• If "9999" is set in the motor constant parameters, tuning data will be invalid and the constant values for Mitsubishi Electric
motors (SF-PR, SF-PR-SC, SF-JR, SF-HR, SF-JRCA, SF-HRCA, SF-V5RU (1500 r/min series), GM-[], GM-DZ, GM-DP, and
so on) are used.
Motor
SF-PR
SF-PR-SC
SF-V5RU (1500 r/min series)
GM-[]
GM-DZ, GM-DP
SF-JR
SF-JR 4P 1.5 kW or lower
SF-HR
SF-JRCA 4P
SF-HRCA
Motor
2
M
)×100(%)
L1×L2
R1: Primary resistance
R2: Secondary resistance
I1: Primary leakage inductance
I2: Secondary leakage inductance
M: Excitation inductance
S: Slip
L1= I1+ M: Primary inductance
L2= I2+ M: Secondary inductance
Name
Motor excitation current (no load
current)
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis
inductance (Ld)
Motor constant (L2)/q-axis
inductance (Lq)
Motor constant (X)
Torque current/Rated PM motor
current
Frequency search gain
Starting resistance tuning
compensation coefficient 1
Starting resistance tuning
compensation coefficient 2
70
30
1800
0 (initial value)
20
40
10
50
30
0 (initial value)
10
Setting range
0 to 500 A, 9999
0 to 50 Ω, 9999
0 to 50 Ω, 9999
0 to 6000 mH, 9999
0 to 6000 mH, 9999
0% to 100%, 9999
0 to 500 A, 9999
0 to 32767, 9999
0% to 200%
0% to 200%
Pr.71 setting
Pr.71 setting
Setting
Initial value
increments
0.01 A
0.001 Ω
0.001 Ω
0.1 mH
0.1 mH
9999
0.1%
0.01 A
1
0.1%
0.1%
15. (C) Motor Constant Parameters
15.2 Offline auto tuning
11
12
13
14
15
16
17
18
19
20
391