Interfaces
Plug connection
Mechanical specifications
Material
Color
Tightening torque (at room temperature)
Permitted ambient conditions
Ambient temperature
Degree of protection
Shock resistant to EN 60068-2-27
Vibration to EN 60068-2-6
Design, dimensions and weight
Dimensions (H x W x D)
Weight
Standards, specifications, approvals
Proof of suitability
MTBF
The values differ for different dimensions/materials of the mounting surface.
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2)
SIMATIC RF600
System Manual, 10/2016, J31069-D0171-U001-A19-7618
During operation
•
During transportation and storage
•
ETSI
•
FCC
•
6.2 RF620A antenna
6GT2812-1EA0x
30 cm coaxial cable with RTNC coupling (for
connection of the antenna cable)
PA 12
Pastel turquoise
≤ 2 Nm
-20 to +70 ℃
•
-40 to +85 °C
•
IP67
50 g
2)
20 g
2)
75 x 75 x 20 mm
100 g
CE (ETSI EN 302208)
•
FCC (Title 47, Part 15.247), cULus
•
1190 years
Antennas
197