Ignitions of gas-air mixtures
The maximum radiated power of the transmitter used to operate the transponder must not
exceed 2000 mW ERP.
Non-compliance with the permitted radiated power can lead to ignitions of gas-air mixtures.
7.8.3.2
Use of the transponder in hazardous areas for dusts
The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are
higher than 190 °C (smoldering temperature). The ignition temperature specified here
according to EN 60079-0 and EN 61241-11 for ignition protection type ic in this case
references the smoldering temperature of a layer of combustible flyings (ic IIIA) or
alternatively non-conductive dusts (ic IIIB).
Temperature class delineation for dusts
Ambient temperature range
-25 °C < Ta < +85 °C
Ignitions of dust-air mixtures
When using the RF610T transponder, make sure that the temperature values are adhered
to in keeping with the requirements of the area of application.
Non-compliance with the permitted temperature ranges while using the transponder can
lead to ignitions of dust-air mixtures.
7.8.4
Technical specifications
Table 7- 24
Product type designation
Radio frequencies
Operating frequency
SIMATIC RF600
System Manual, 10/2016, J31069-D0171-U001-A19-7618
WARNING
WARNING
Technical specifications of the transponder SIMATIC RF610T special variant ATEX
ETSI
FCC
7.8 SIMATIC RF610T ATEX
Temperature value
T120 °C
SIMATIC RF610T special variant ATEX
865 to 868 MHz
902 to 928 MHz
Transponder